Clean Air System

Showing all 6 results

Filter
  • Clean Air System

    Air Curtain (Walk Through Barrier) MSW-169

    Add to Quote
    • Creates a barrier/curtain of high-speed downflow air (15 meters/sec) between a clean room and an unconditioned open room/area.
    • Helps in energy savings of air-conditioned room.
    • Outer body made of heavy gauge CRC sheet duly powder coated.
    • Fitted with heavy and continuous rating double shaft motor fitted with dual blowers for uniform and high-speed layer air which forms an invisible layer of the curtain
  • Clean Air System

    Air Purification Tower MSW-184

    Add to Quote
    • Pre Filter: For course particulates of 10 microns.
    • HEPA Filter: For Particulates & micro-organisms down to 0.3 microns with 99.97% efficiency, DOP Tested.
    • Activated Carbon Filter: For Fumes & Odours.
    • Activated Alumina Filter: For Volatile Organic Compounds & Chemicals Airborne Contaminants.
    • Potassium Permanganate: For Germicidal action.
    • UV Light: For destroying Organic Contaminants.
    • Ozone Lamp (optional): For Aesptesizing the Air.
    • Electrostatic Precipitator: For Fine Airborne Particulates (optional).
    • Negative ION Generator: For Air Freshness (optional)
    • Effective Coverage: 400 Sq. ft. (37 sq. m)
    • Max. Air Flow: 500cu. ft./min (850 cu.m./hr)
    • HEPA Filter Capacity: 650 cfm, ie of 25% over rated capacity for longer life.
    • Air Filtration Cycle / Hr.: 7.5 (in 400 sq. ft ×10′ ht room)
    • Construction is of heavy CRCA powder coated after 7-tank pretreatement. SS-304 is available an optional Castor Wheels & Mains Lead storage for easy mobility.
    • Dimensions: 27”(W)×18”(D)×42”(H) : 690mm×460mm×1070mm
    • Filter Choke Indicator: Continuously indicates filter choke status.
  • Clean Air System

    Air Shower MSW-165

    Add to Quote
    • Available in various sizes according to users requirement.
    • Highly effective HEPA filtered air having cleanliness level as high as 99.99% with cold DOP and 99.97% with HOT DOP retaining airborne particles of size 0.3 micron.
    • Pre-filter installed before HEPA filter to the extended life of HEPA filter.
    • Advance Microprocessor Control System.
    • High efficiency statically & dynamically balanced motor blower assembly.
  • Clean Air System

    Dynamic Pass Box MSW-183

    Add to Quote
    • It is a rectangular compartment with two doors at its extreme.
    • It helps in achieving the aim of material transfer without disturbing the cleanliness level of the room.
    • Hinged doors are provided with a glass viewing window through which the material kept for transfer can be seen.
    • One of the doors opens in the cleanroom whereas the other door opens in the other room.
    • These doors are electrically inter-locked type so that only one door can be opened at a time.
    • This avoids the direct flow of air from the cleanroom to the other room or vice-versa.
    • This also prevents the need to open the cleanroom door frequently for transferring of material from and into the cleanroom.
    • So, it helps in fulfilling the purpose of material transfer without disturbing the cleanliness level of the cleanroom.
    • These dynamic units are specially designed Pass Boxes fitted with HEPA Filter and motor blower unit.
    • The motor blower unit automatically starts at the time of opening any of the doors.
    • This complete setup acts as a pressure chamber and only clean air enters the clear room thus maintaining the cleanliness level of a cleanroom.
  • Clean Air System

    PCR Hood MSW-160

    Add to Quote
    • HEPA Filtration: Equipped with an H14 HEPA filter that offers 99.995% efficiency for particles sized 0.1–0.2 µm, ensuring a Class 100 (ISO 5) clean environment within the work area.
    • Dual Air Barrier Configurations: Offers both inward and outward air barrier configurations, selectable through a simple mechanical operation, to suit various experimental needs.
    • Stainless Steel Work Surface: Features a removable perforated work surface and back wall made of AISI 304 stainless steel for easy cleaning and maintenance.
    • Tempered Glass Panels: Constructed with front panels of tempered glass and a hinged front window, providing clear visibility and safety.
    • User-Friendly Controls: Includes soft-touch keys on the control panel for controlling the fan and fluorescent lighting, enhancing user convenience.
    • Optional Accessories: Available with optional features such as an elapsed time meter for the HEPA filter, a tubular stand, and a UV lamp for added functionality.
  • Clean Air System

    Static Pass Box MSW-183

    Add to Quote
    • Cabinet is fabricated of Stainless Steel (SS-304).
    • It is a rectangular compartment with two doors at its extreme.
    • It helps in achieving the aim of material transfer without disturbing the cleanliness level of the room.
    • Hinged doors are provided with a glass viewing window through which the material kept for transfer can be seen.
    • One of the doors opens in the cleanroom whereas the other door opens in the other room.
    • These doors are electrically inter-locked type so that only one door can be opened at a time.
    • This avoids the direct flow of air from the cleanroom to the other room or vice-versa.
    • This also prevents the need to open the cleanroom door frequently for transferring of material from and into the cleanroom.
    • So, it helps in fulfilling the purpose of material transfer without disturbing the cleanliness level of the cleanroom.

Review Your Cart
0
Add Coupon Code
Subtotal

 
Scroll to Top